Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Physiol ; 15: 1356787, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38434139

RESUMO

Exposure of experimental rodents to controlled cycles of light, food, and temperature is important when investigating alterations in circadian cycles that profoundly influence health and disease. However, applying such stimuli simultaneously is difficult in practice. We aimed to design, build, test, and open-source describe a simple device that subjects a conventional mouse cage to independent cycles of physiologically relevant environmental variables. The device is based on a box enclosing the rodent cage to modify the light, feeding, and temperature environments. The device provides temperature-controlled air conditioning (heating or cooling) by a Peltier module and includes programmable feeding and illumination. All functions are set by a user-friendly front panel for independent cycle programming. Bench testing with a model simulating the CO2 production of mice in the cage showed: a) suitable air renewal (by measuring actual ambient CO2), b) controlled realistic illumination at the mouse enclosure (measured by a photometer), c) stable temperature control, and d) correct cycling of light, feeding, and temperature. The cost of all the supplies (retail purchased by e-commerce) was <300 US$. Detailed technical information is open-source provided, allowing for any user to reliably reproduce or modify the device. This approach can considerably facilitate circadian research since using one of the described low-cost devices for any mouse group with a given light-food-temperature paradigm allows for all the experiments to be performed simultaneously, thereby requiring no changes in the light/temperature of a general-use laboratory.

2.
HardwareX ; 15: e00457, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37538251

RESUMO

An unacceptably large number of newborn infants die in developing countries. For a considerable number of cases (particularly in preterm infants), morbidity and mortality can be reduced by simply maintaining newborn thermal homeostasis during the first weeks of life. Unfortunately, deaths caused by prematurity remain inordinately common in low- and middle-income countries (LMICs) due to reduced access to incubators in light of the high cost of commercially available devices. We herein describe and test a low-cost and easy-to-assemble neonatal incubator created with inexpensive materials readily available in LMICs. The incubator is based on an Arduino microcontroller. It maintains controlled temperature and relative humidity inside the main chamber while continuously measuring newborn weight progress. Moreover, the incubator has a tilting bed system and an additional independent safety temperature alarm. The performance of the novel low-cost neonatal incubator was evaluated and successfully passed the IEC 60601-2-19 standards. In the present work, we provide all the necessary technical information, which is distributed as open source. This will enable assembly of very low-cost (<250 €) and fully functional incubators in LMICs that should help reduce neonatal mortality.

3.
J Clin Med ; 11(18)2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36143070

RESUMO

BACKGROUND: Negative (vacuum) pressure therapy promotes wound healing. However, commercially available devices are unaffordable to most potential users in low- and middle-income countries (LMICs), limiting access to many patients who could benefit from this treatment. This study aimed to design and test a cheap and easy-to-build negative pressure device and provide its detailed open-source description, thereby enabling free replication. METHODS: the negative pressure device was built using off-the-shelf materials available via e-commerce and was based on a small pump, a pressure transducer, and the simplest Arduino controller with a digital display (total retail cost ≤ 75 US$). The device allows the user to set any therapeutic range of intermittent negative pressure and has two independent safety mechanisms. The performance of the low-cost device was carefully tested on the bench using a phantom wound, producing a realistic exudate flow rate. RESULTS: the device generates the pressure patterns set by the user (25-175 mmHg of vacuum pressure, 0-60 min periods) and can drain exudate flows within the clinical range (up to 1 L/h). CONCLUSIONS: a novel, low-cost, easy-to-build negative pressure device for wound healing displays excellent technical performance. The open-source hardware description provided here, which allows for free replication and use in LMICs, will facilitate the application and wider utilization of this therapy to patients.

4.
Front Med (Lausanne) ; 9: 938949, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35979205

RESUMO

Assessing tidal volume during mechanical ventilation is critical to improving gas exchange while avoiding ventilator-induced lung injury. Conventional flow and volume measurements are usually carried out by built-in pneumotachographs in the ventilator or by stand-alone flowmeters. Such flow/volume measurement devices are expensive and thus usually unaffordable in low-resource settings. Here, we aimed to design and test low-cost and technically-simple calibration and assembly pneumotachographs. The proposed pneumotachographs are made by manual perforation of a plate with a domestic drill. Their pressure-volume relationship is characterized by a quadratic equation with parameters that can be tailored by the number and diameter of the perforations. We show that the calibration parameters of the pneumotachographs can be measured through two maneuvers with a conventional resuscitation bag and by assessing the maneuver volumes with a cheap and straightforward water displacement setting. We assessed the performance of the simplified low-cost pneumotachographs to measure flow/volume during mechanical ventilation as carried out under typical conditions in low-resource settings, i.e., lacking gold standard expensive devices. Under realistic mechanical ventilation settings (pressure- and volume-control; 200-600 mL), inspiratory tidal volume was accurately measured (errors of 2.1% on average and <4% in the worst case). In conclusion, a simple, low-cost procedure facilitates the construction of affordable and accurate pneumotachographs for monitoring mechanical ventilation in low- and middle-income countries.

5.
Artigo em Inglês | MEDLINE | ID: mdl-34948991

RESUMO

High ambient temperature and humidity greatly increase the risk of hyperthermia and mortality, particularly in infants, who are especially prone to dehydration. World areas at high risk of heat stress include many of the low- and middle-income countries (LMICs) where most of their inhabitants have no access to air conditioning. This study aimed to design, evaluate, and test a novel low-cost and easy-to-assemble device aimed at preventing the risk of infant hyperthermia in LMICs. The device is based on optimizing negative heat transfer from a small amount of ice and transferring it directly to the infant by airflow of refrigerated air. As a proof of concept, a device was assembled mainly using recycled materials, and its performance was assessed under laboratory-controlled conditions in a climatic chamber mimicking realistic stress conditions of high temperature and humidity. The device, which can be assembled by any layperson using easily available materials, provided sufficient refrigerating capacity for several hours from just 1-2 kg of ice obtained from a domestic freezer. Thus, application of this novel device may serve to attenuate the adverse effects of heat stress in infants, particularly in the context of the evolving climatic change trends.


Assuntos
Transtornos de Estresse por Calor , Hipertermia Induzida , Temperatura Alta , Humanos , Umidade
6.
Eur Respir J ; 55(6)2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32312862

RESUMO

AIM: Current pricing of commercial mechanical ventilators in low-/middle-income countries (LMICs) markedly restricts their availability, and consequently a considerable number of patients with acute/chronic respiratory failure cannot be adequately treated. Our aim was to design and test an affordable and easy-to-build noninvasive bilevel pressure ventilator to allow a reduction in the serious shortage of ventilators in LMICs. METHODS: The ventilator was built using off-the-shelf materials available via e-commerce and was based on a high-pressure blower, two pressure transducers and an Arduino Nano controller with a digital display (total retail cost <75 USD), with construction details provided open source for free replication. The ventilator was evaluated, and compared with a commercially available device (Lumis 150 ventilator; Resmed, San Diego, CA, USA): 1) in the bench setting using an actively breathing patient simulator mimicking a range of obstructive/restrictive diseases; and b) in 12 healthy volunteers wearing high airway resistance and thoracic/abdominal bands to mimic obstructive/restrictive patients. RESULTS: The designed ventilator provided inspiratory/expiratory pressures up to 20/10 cmH2O, respectively, with no faulty triggering or cycling; both in the bench test and in volunteers. The breathing difficulty score rated (1-10 scale) by the loaded breathing subjects was significantly (p<0.005) decreased from 5.45±1.68 without support to 2.83±1.66 when using the prototype ventilator, which showed no difference with the commercial device (2.80±1.48; p=1.000). CONCLUSION: The low-cost, easy-to-build noninvasive ventilator performs similarly to a high-quality commercial device, with its open-source hardware description, which will allow for free replication and use in LMICs, facilitating application of this life-saving therapy to patients who otherwise could not be treated.


Assuntos
Respiração com Pressão Positiva , Ventiladores Mecânicos , Estudos de Viabilidade , Humanos , Inalação , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...